Source code for abaqus.StepMiscellaneous.Control

import typing

from abaqusConstants import *


[docs]class Control: """The Control object is used to provide additional optional general solution controls. Notes ----- This object can be accessed by: .. code-block:: python import step mdb.models[name].steps[name].control """
[docs] def setValues(self, allowPropagation: Boolean = ON, resetDefaultValues: Boolean = OFF, discontinuous: Boolean = OFF, constraints: typing.Union[SymbolicConstant, float] = DEFAULT, lineSearch: typing.Union[SymbolicConstant, float] = DEFAULT, timeIncrementation: typing.Union[SymbolicConstant, float] = DEFAULT, directCyclic: typing.Union[SymbolicConstant, float] = DEFAULT, concentrationField: typing.Union[SymbolicConstant, float] = DEFAULT, displacementField: typing.Union[SymbolicConstant, float] = DEFAULT, electricalPotentialField: typing.Union[SymbolicConstant, float] = DEFAULT, globalField: typing.Union[SymbolicConstant, float] = DEFAULT, hydrostaticFluidPressureField: typing.Union[SymbolicConstant, float] = DEFAULT, poreFluidPressureField: typing.Union[SymbolicConstant, float] = DEFAULT, rotationField: typing.Union[SymbolicConstant, float] = DEFAULT, temperatureField: typing.Union[SymbolicConstant, float] = DEFAULT, vcctLinearScaling: typing.Union[SymbolicConstant, float] = DEFAULT): """This method modifies the Control object. Parameters ---------- allowPropagation A Boolean specifying whether to allow all control values to propagate from a previous step. Setting this argument to ON automatically sets *resetDefaultValues* to OFF. The default value is ON. resetDefaultValues A Boolean specifying whether to use all default control values. Setting this argument to ON automatically sets *allowPropagation* to OFF. The default value is OFF. discontinuous A Boolean specifying whether to set *timeIncrementation* values that will usually improve efficiency for analyses with severely discontinuous behavior. The default value is OFF. constraints The SymbolicConstant DEFAULT or a sequence of Floats specifying tolerances on constraint equations. If a specified sequence contains a value of 0, that item in the sequence will be set to its system-defined value. The value can also be the SymbolicConstant DEFAULT. The default value is DEFAULT. lineSearch The SymbolicConstant DEFAULT or a sequence of Floats specifying line search control parameters. If a specified sequence contains a value of 0, that item in the sequence will be set to its system-defined value. The value can also be the SymbolicConstant DEFAULT. The default value is DEFAULT. timeIncrementation The SymbolicConstant DEFAULT or a sequence of Floats specifying time incrementation control parameters. If a specified sequence contains a value of 0, that item in the sequence will be set to its system-defined value. The value can also be the SymbolicConstant DEFAULT. The default value is DEFAULT. directCyclic The SymbolicConstant DEFAULT or a sequence of Floats specifying direct cyclic control parameters. If a specified sequence contains a value of 0, that item in the sequence will be set to its system-defined value. The value can also be the SymbolicConstant DEFAULT. The default value is DEFAULT. concentrationField The SymbolicConstant DEFAULT or a sequence of Floats specifying mass concentration field equilibrium equation parameters. If a specified sequence contains a value of 0, that item in the sequence will be set to its system-defined value. The value can also be the SymbolicConstant DEFAULT. The default value is DEFAULT. displacementField The SymbolicConstant DEFAULT or a sequence of Floats specifying displacement field and warping degree of freedom field equilibrium equation parameters. If a specified sequence contains a value of 0, that item in the sequence will be set to its system-defined value. The value can also be the SymbolicConstant DEFAULT. The default value is DEFAULT. electricalPotentialField The SymbolicConstant DEFAULT or a sequence of Floats specifying electrical potential field equilibrium equation parameters. If a specified sequence contains a value of 0, that item in the sequence will be set to its system-defined value. The value can also be the SymbolicConstant DEFAULT. The default value is DEFAULT. globalField The SymbolicConstant DEFAULT or a sequence of Floats specifying parameters for all applicable field equilibrium equations. This argument overwrites all other field equilibrium equation control values. If a specified sequence contains a value of 0, that item in the sequence will be set to its system-defined value. The value can also be the SymbolicConstant DEFAULT. The default value is DEFAULT. hydrostaticFluidPressureField The SymbolicConstant DEFAULT or a sequence of Floats specifying hydrostatic fluid element volume constraint parameters. If a specified sequence contains a value of 0, that item in the sequence will be set to its system-defined value. The value can also be the SymbolicConstant DEFAULT. The default value is DEFAULT. poreFluidPressureField The SymbolicConstant DEFAULT or a sequence of Floats specifying pore liquid volumetric continuity equilibrium equation parameters. If a specified sequence contains a value of 0, that item in the sequence will be set to its system-defined value. The value can also be the SymbolicConstant DEFAULT. The default value is DEFAULT. rotationField The SymbolicConstant DEFAULT or a sequence of Floats specifying rotation field equilibrium equation parameters. If a specified sequence contains a value of 0, that item in the sequence will be set to its system-defined value. The value can also be the SymbolicConstant DEFAULT. The default value is DEFAULT. temperatureField The SymbolicConstant DEFAULT or a sequence of Floats specifying temperature field equilibrium equation parameters. If a specified sequence contains a value of 0, that item in the sequence will be set to its system-defined value. The value can also be the SymbolicConstant DEFAULT. The default value is DEFAULT. vcctLinearScaling The SymbolicConstant DEFAULT or a Float specifying linear scaling parameter for a VCCT debonding analysis. If a specified value is 0, it will be set to its system-defined value. The value can also be the SymbolicConstant DEFAULT. The default value is DEFAULT. Raises ------ RangeError """ pass